logo
Shandong Jingwei Steel Manufacturing Co., Ltd.
Email admin@sdjws.com TEL: 86-13501001767
Home > PRODUCTS > Steel Pipe Steel Tube >
Seamless Boiler Tube ASTM A192 A179 Carbon Steel OD 51mm Wall 3.5mm 11.8m for Superheater
  • Seamless Boiler Tube ASTM A192 A179 Carbon Steel OD 51mm Wall 3.5mm 11.8m for Superheater
  • Seamless Boiler Tube ASTM A192 A179 Carbon Steel OD 51mm Wall 3.5mm 11.8m for Superheater

Seamless Boiler Tube ASTM A192 A179 Carbon Steel OD 51mm Wall 3.5mm 11.8m for Superheater

Place of Origin China
Brand Name Jingwei
Certification ISO 9001:2015, ASTM A192 / A179, EN 10204 3.1
Model Number JW-BLR-A192
Product Details
Standard:
ASTM A192 / ASTM A179
Wall Control:
Minimum Wall, Plus 20 Percent / Minus 0 Percent
Test:
Eddy Current 100 Percent
Highlight: 

ASTM A192 boiler tube

,

A179 seamless boiler tube

,

51mm superheater tube

Payment & Shipping Terms
Minimum Order Quantity
2 tons
Price
USD 850 - 1080 per ton FOB Tianjin
Packaging Details
Hexagonal bundle, caps, waterproof wrapping, end protectors
Delivery Time
15 - 25 days after deposit
Payment Terms
T/T 30% deposit, balance against B/L copy; L/C at sight
Supply Ability
1500 tons per month
Product Description

Boiler tube is bought on minimum wall, not average wall. A tube ordered at 3.5 mm average wall can legally contain sections at 3.1 mm, and that is where a superheater fails after a few thousand thermal cycles. Our A192 and A179 boiler tube is produced and certified to minimum wall, so the thinnest point of every length is at or above 3.5 mm, and wall thickness is verified by ultrasonic measurement along the full length rather than at the ends only.

A179 covers low carbon steel heat exchanger and condenser tubes with a minimum wall requirement, while A192 covers seamless carbon steel boiler tubes for high pressure service with tighter chemistry and a mandatory hydrostatic test. Both are supplied here at 51 mm outside diameter, 3.5 mm minimum wall and 11.8 m length, with 100 percent eddy current testing to detect longitudinal and transverse defects before the tube goes into a boiler bank.

Key Features
  • Minimum wall certification: every length is certified against minimum wall, not average wall, which is the number boiler designers actually calculate with.
  • 100 percent eddy current test: full length inspection for longitudinal and transverse defects, with the report supplied per bundle.
  • A179 and A192 in one supply: economiser and superheater tubes can be ordered together with separate certificates.
  • Controlled grain structure: normalized or as-rolled condition matched to the grade so the tube bends and expands without cracking.
  • 11.8 m length: fewer shop welds in the boiler bank and less scrap at the header end.
  • Bend and weld support: we can supply U-bent or swaged tubes through qualified bending shops on request.
  • End protection: both ends capped and the bevel or plain end protected for the sea voyage.
Technical Specifications
ParameterSpecification
ProductSeamless carbon steel boiler tube
StandardASTM A192, ASTM A179, ASME SA192, SA179
Outside diameter19 mm - 133 mm
Wall thickness2.0 mm - 12 mm, minimum wall control
Length11.8 m, 6 m, or cut to order
GradeA192, A179, A210 Gr.A1 / C
Tensile strength325 MPa minimum (A179), 415 MPa minimum (A192)
Yield strength180 MPa minimum (A179), 255 MPa minimum (A192)
TestHydrostatic and 100 percent eddy current
SurfaceBare, pickled, or black varnished
EndsPlain, beveled, or swaged
PackingHexagonal bundle with end caps and waterproof wrap
Applications

Applications are superheater and reheater tubes, economiser coils, water wall panels, boiler bank tubes, feedwater heaters and heat exchanger bundles in power stations, waste heat recovery boilers and industrial steam plants. A179 is used where the tube sees lower temperature but must still hold a minimum wall, while A192 is specified for higher pressure boiler service.

Replacement tube orders are usually urgent, so we keep common sizes of A179 and A192 in stock and can ship cut lengths within a week. Send the original tube drawing or the boiler manufacturer's part number and we will match the outside diameter, minimum wall, length and end preparation instead of quoting the nearest standard size.

Inspection, Documentation and Packaging

Inspection includes chemistry per heat, tensile and yield per lot, flattening and flaring tests, hardness, hydrostatic testing of every length and 100 percent eddy current testing along the full length. Wall thickness is measured ultrasonically at intervals along the tube, and the minimum reading is recorded on the certificate for each bundle.

Tubes are bundled hexagonally, capped at both ends, wrapped in waterproof paper and protected with wooden or plastic end rings. For U-bent tubes we use stack-rack boxing with the bend radius supported, because an unsupported U-bend will ovalize in transit and the tube will not pass the plug gauge on site.

Buyer Questions We Answer Before Ordering

Do you certify minimum wall or average wall? Minimum wall. The certificate reports the lowest measured wall per bundle, and the ultrasonic records are available on request.

Can you bend the tubes to our radius? Yes, through qualified bending shops with eddy current testing before and after bending and stress relief annealing after bending.

How fast can you ship replacement tubes? Common A179 and A192 sizes ship within 7 to 10 days from stock; non-stock sizes take 15 to 25 days.

Contact Us at Any Time

86-13501001767
Dongchangfu District Industrial Park, Liaocheng City, Shandong Province, China
Send your inquiry directly to us